Friday, September 10, 2010
   
Text Size

Patene Artectura Acid Stain

Guideline Specification

1.00 GENERAL

1.01 Description - The work in this section shall be

designated as PATÈNE ARTECTURA by Bomanite in the

plans. The work shall include all labor, materials and

equipment to complete the installation.

1.02 References - The contractor for this work shall be

a Licensed Bomanite Contractor who has been trained

and equipped by:

Bomanite Corporation

P.O. Box 599

Madera, CA 93639-0599

Tel: (559) 673-2411

Fax: (559) 673-8246

Web site: www.bomanite.com

E-mail: This e-mail address is being protected from spambots. You need JavaScript enabled to view it

The Licensed Bomanite Contractor in this area is:

Name ___________________________________________

Address __________________________________________

_________________________________________________

Phone____________________________________________

1.03 Definitions - PATÈNE ARTECTURA by

Bomanite, a system which employs various coloring,

etching, texturing, scoring and patterning techniques to

produce specialty architectural concrete finishes. The work

is performed on the job site by trained and experienced

workmen.

1.04 (Optional) Related Work - to be completed

by a qualified contractor.

a. Preparation work, including sub-grade preparation,

compaction, finish grading, construction of formwork,

placement of screeds, and installation of

reinforcement, when required, shall be done

by a qualified contractor(s).

b. Provide and install concrete color as specified

elsewhere.

c. Provide, place and finish concrete as specified

elsewhere.

d. Provide all necessary or required special concrete

preparation as specified elsewhere.

e. Provide all necessary repair and patch work.

1.05 Quality Assurance

a. All work shall be installed by a Licensed Bomanite

Contractor who shall provide a foreman or supervisor

who has experience with and knowledge of specialty

architectural concrete finishes using the PATÈNE

ARTECTURA system. Evidence that the Licensed

Bomanite Contractor is qualified to complete the project

as specified herein shall be submitted to, and subject to

the approval of, the Architect.

b. The Licensed Bomanite Contractor shall

provide a jobsite sample (100 square feet

or 9.3 square meters minimum) to be

approved by the Architect prior to the start

of the construction. Said sample shall be

the standard for the balance of the work

installed, and shall be protected against

damage until final approval from the

Architect. The cost for the construction and

protection of the referee sample shall be

borne by the owner/agent and shall be

part of the contractor’s bid.

2.00 PRODUCTS AND MATERIALS

a. Concrete Mix Design (Optional): The concrete shall have

a minimum compressive strength of 3,000 psi (21 MPa)

in non-freeze areas, 3,500 psi (24 MPa) in moderate

freeze-thaw areas, and 4,000 psi (28 MPa) in severe

freeze-thaw areas. Portland cement shall conform to

ASTM C 150 Type I, II, or V, depending on soil

conditions. Aggregates shall conform to ASTM C 33.

Mixing water shall be fresh, clean and potable. In

freeze-thaw areas only, an air-entraining agent

complying with ASTM C 260 shall be used to achieve

an entrained air content for the particular mix used that is

in accordance with the published recommendations of

the Portland Cement Association and the American

Concrete Institute. No admixtures containing calcium

chloride shall be permitted.

b. Reinforcement (Optional): All cast-in-place concrete shall,

whether horizontal or vertical, be reinforced in

accordance with the guidelines and recommendations

of the American Concrete Institute.

c. Bomanite Color Hardener (Optional): Freshly placed

concrete shall be colored using the following

Bomanite Color Hardener:

____________________________________________

____________________________________________

d. Bomanite Chemical Stain (Optional): The

architectural concrete shall be colored using the

following Bomanite Chemical Stain(s):

____________________________________________

____________________________________________

e. Bomanite Con-Color: The architectural concrete shall

be colored using the following Bomanite

Con-Color(s):__________________________________

____________________________________________

f. Bomanite Sealer: The surface shall be sealed using the

following Bomanite Sealer (Optional: Tinted Sealer):

____________________________________________

____________________________________________

PATÈNE ARTECTURA® by ®

Bulletin 205.3

3.00 EXECUTION

3.01 Installation Procedure

a. If new concrete is to be poured, the sub-grade should

be prepared in accordance with the recommendations

of the soils engineer and the American Concrete

Institute. The reinforcement should be placed in

accordance with the guidelines of the American

Concrete Institute. The concrete should be placed and

finished in accordance with accepted industry

standards. The concrete should be allowed to cure for a

period of at least 28 days prior to the application of the

stain(s). Liquid membrane cures or plastic sheeting

should not be used. The new concrete should be cured

using either curing paper or wet curing methods.

b. Optional: Bomanite Color Hardener shall be applied

evenly to the plastic surface by the dry-shake method

using a minimum of 60 pounds per 100 square feet

(27.2 KG per 9.3 square meters). It shall be applied

in two or more shakes, floated after each shake and

troweled only after the final floating.

c. Optional: The Licensed Bomanite Contractor shall

provide all decorative jointing and finishes in designated

areas and in accordance with the Architect’s direction.

d. The contractor shall patch and repair all defects in the

surface.

e. The substrate shall be free of all debris, oils, grease,

curing compounds, sealers, etc. prior to the

application of the chemical stain(s) and/or sealer(s).

f. To stabilize “dusty” or soft surfaces due to improper

curing/finishing techniques and provide waterproofing

protection against moisture problems, apply Bomanite

Con-Shield per manufacturer’s recommendations. (See

Bomanite Con-Shield Technical Bulletin)

g. If concrete slabs have been burnished with finishing

machines and are found to be highly polished,

lightly etch the surface using Bomanite Con-Clean

prior to the staining application.

h. Optional: Bomanite Chemical Stain shall be applied

to the clean substrate in a minimum of two coats at a

rate of 300 to 600 square feet (18.6 to 37.2 square

meters) per U.S. gallon, per coat. The stain shall be

applied in accordance with the manufacturer’s

recommendations. (See Bomanite Chemical Stain

Technical Bulletin)

i. Optional: Bomanite Con-Color shall be applied to the

clean (free of cures, sealer, etc.) substrate in

accordance with the manufacturer’s recommendations.

(See Bomanite Con-Color Technical Bulletin)

j. The surface shall be sealed using Bomanite Sealer in

accordance with the manufacturer’s recommendations

to complete the coloring process.

CODES, CERTIFICATION

All materials manufactured by Bomanite Corporation are

warranted to be of uniform quality within manufacturing

tolerances. Since control is not exercised over their use, no

warranty, expressed or implied, is made as to the effects of

such use. Bomanite Corporation’s obligation under this

warranty shall be limited to refunding the purchase price of

that portion of the material proven to be defective. Please

contact your local Bomanite contractor for available

warranties on workmanship. Bomanite Corporation makes

no warranty, expressed or implied, as to the quality of the